Microfluidic bead trap as a visual bar for quantitative detection of oligonucleotides.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 28869261.
- Also identified by DOI 10.1039/c7lc00836h.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We demonstrate a microfluidic bead trap capable of forming a dipstick-type bar visible to the naked eye for simple and quantitative detection of oligonucleotides. We use magnetic microparticles (MMPs) and polystyrene microparticles (PMPs) that are connected and form MMPs-targets-PMPs when target oligonucleotides are present, leaving free PMPs with a number inversely proportional to the amount of targets. Using a capillary flow-driven microfluidic circuitry consisting of a magnetic separator to remove the MMPs-targets-PMPs, the free PMPs can be trapped at the narrowing nozzle downstream, forming a visual bar quantifiable based on the length of PMP accumulation. Such a power-free and instrument-free platform enables a limit of detection at 13 fmol (0.65 nM in 20 μl, S/N = 3) of oligonucleotides and is compatible with single-nucleotide polymorphisms and operation in a complex bio-fluid. Moreover, using DNAzyme as the target oligonucleotide that catalyzes a specific hydrolytic cleavage in the presence of lead ions, we demonstrate a model application that detects lead ions with a limit of detection of 12.2 nM (2.5 μg l<sup>-1</sup>), providing quantitative and visual detection of lead contamination at resource-limited sites.
Medical subject headings
- Microfluidic Analytical Techniques
- Microspheres
- Oligonucleotides