Comparison of metal ion levels in patients with hip resurfacing versus total hip arthroplasty.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 28878517.
- Also identified by DOI 10.1016/j.jor.2017.07.019 and PMC identifier 5581379.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Mechanical wear at the articular surface and corrosive processes at modular junctions, such as the trunnion, are responsible for metal ions production. We retrospectively reviewed 64 patients who underwent THA with a metal on metal bearing surface and 34 patients with hip Resurfacing. Metal ion measurements, six-week post-op radiographs, and functional scores were included in the analysis. Cobalt ion levels were significantly elevated in THA patients, 2.95 μg/L as compared to resurfacing patients, (2.95 versus 1.30 μg/L, p < 0.0005). Chromium levels were not significantly different between THA patients and resurfacing patients (1.05 versus 1.00 μg/L, p = 0.529).
Anatomy
- hip