Validity, reliability and minimal detectable change of the balance evaluation systems test (BESTest), mini-BESTest and brief-BESTest in patients with end-stage renal disease.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 28886676.
- Also identified by DOI 10.1080/09638288.2017.1375034.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study determined the validity, test-retest reliability and minimal detectable change of the balance evaluation systems test (BESTest), mini-balance evaluation systems test (Mini-BESTest) and brief-balance evaluation systems test (Brief-BESTest) in patients with end-stage renal disease. A cross-sectional study with 74 patients with end-stage renal disease (male 66.2%; 63.9 ± 15.1 years old) was conducted. Participants were asked to report the number of falls during the previous 12 months and to complete the activity-specific balance confidence (ABC) scale. The BESTest was administered, and the Mini-BESTest and Brief-BESTest scores were computed based on the BESTest performance. Validity was assessed by correlating balance tests with each other and with the ABC scale. Test-retest relative reliability and agreement were explored with the intraclass correlation coefficient (ICC) equation (2,1) and the Bland and Altman method. Minimal detectable changes at the 95% confidence level were established. Balance test scores were significantly correlated with each other (spearman's correlation = 0.89-0.92) and with the ABC scale (spearman's correlation = 0.49-0.59). Balance tests presented high test-retest reliability (ICC = 0.84-0.94), with no evidence of bias. Minimal detectable change values were 10.8 (expressed as a percentage 13.5%), 5.3 (23.7%) and 5.6 (34%) points for the BESTest, Mini-BESTest and Brief-BESTest, respectively. All tests are valid and reliable to assess balance in patients with end-stage renal disease. Nevertheless, based on the minimal detectable changes found, BESTest and Mini-BESTest may be the most recommended tests for this specific population. Implications for Rehabilitation Balance evaluation systems test (BESTest), mini-balance evaluation systems test (Mini-BESTest) and brief-balance evaluation systems test (Brief-BESTest) are reliable and valid in patients with end stage renal disease (ESRD). The minimal detectable changes of 10.8 for the BESTest, 5.3 for the Mini-BESTest and 5.6 for the Brief-BESTest can be used by clinicians to identify a true change in balance over time or in response to interventions. Based on the minimal detectable changes found, BESTest and Mini-BESTest may be the most recommended; and the selection of one of them may be based on time and equipment availability.
Medical subject headings
- Accidental Falls
- Disability Evaluation
- Postural Balance