HPLC-MS/MS: A potential method to track the in vivo degradation of zein-based biomaterial.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 28960906.
- Also identified by DOI 10.1002/jbm.a.36252.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Given the inadequacies of existing clinic tracking strategies, such as isotopic tracer techniques, one of the major thrusts in protein-based tissue engineering substitutes prior to use in clinic is to develop a safe technique that can effectively track their degradation in vivo. Keeping in view the possible application of a natural polymer, zein as a novel bone substitute, with the advantages of good bio-compatibility, bio-degradability and outstanding mechanical properties, we attempted here to construct a HPLC-MS/MS method to track the in vivo degradation of zein porous scaffold. Histological observation and immunohistochemistry analysis using the intramuscular implantation model of rats clearly indicated that zein porous scaffold has certain osteoinductive ability. More importantly, HPLC-MS/MS detected the changes of amino acids levels in plasma and different organs after the implantation of scaffolds. With these findings, it could be concluded that HPLC-MS/MS might be a potential method to track the in vivo degradation of protein-based tissue engineering substitutes. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 606-613, 2018.
Medical subject headings
- Biocompatible Materials
- Tandem Mass Spectrometry
- Zein