Scalp simulation - A novel approach to site-specific biomechanical modeling of the skin.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 28961517.
- Also identified by DOI 10.1016/j.jmbbm.2017.09.024.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study aimed to determine the hardness of the human scalp in vivo in order to identify an appropriate scalp simulant, from a range of commercially available silicone materials, for force impact assessment. Site-dependent variation in scalp hardness, and the applicability of contemporary skin simulants to the scalp were also considered. A Shore A-type durometer was used to collected hardness data from the scalps of 30 human participants (five males and five females in each of the three age categories: 18-30, 31-40, 41-50) and four commercially available silicones (light, medium, and heavy-bodied PVS, and duplication silicone). One-sample t-tests were used to compare the mean hardness of simulants to that of the scalp. Site-dependent variation in the hardness of the scalp was assessed using a mixed-model repeated measures ANOVA. Mean human scalp hardness derived from participants was 20.6 Durometer Units (DU; SD = 3.4). Analysis revealed only the medium-bodied PVS to be an acceptable scalp simulant when compared to the mean hardness of the human scalp (p = 0.869). Scalp hardness varied significantly anteroposteriorly (with an observable linear trend, p < 0.001), but not mediolaterally (p = 0.271). Comparisons of simulants to site-specific variation in scalp hardness anteroposteriorly found the medium-bodied PVS to be only suitable in the central region of the scalp (p = 0.391). In contrast, the duplication silicone (p = 0.074) and light-bodied PVS (p = 0.147) were only comparable to the posterior region. Contemporary skin simulants fail to accurately represent the scalp in terms of hardness. There is strong support for the use of medium-bodied PVS as a scalp simulant. Human scalp hardness varies significantly anteroposteriorly, but not mediolaterally, corresponding to regional anatomical variation within the scalp. A number of materials were identified as potential simulants for different regions of the scalp when more site-specific simulant research is required.
Medical subject headings
- Materials Testing
- Scalp
- Silicone Elastomers
- Silicones
- Skin Physiological Phenomena