Preventing Wedge Deformities When Treating Intertrochanteric Femur Fractures With Intramedullary Devices: A Technical Tip.
expert_opinion · Level V
Where this comes from
- Record sourced from PubMed, PMID 29040234.
- Also identified by DOI 10.1097/BOT.0000000000001033.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Intertrochanteric femur fractures are common injuries associated with significant patient morbidity and mortality and high societal costs. Although intramedullary devices have shown promises for treating a wide range of intertrochanteric femur fractures, improper technique can lead to malalignment, fracture displacement, and/or iatrogenic fractures. In particular, a "wedge effect" has been described, in which the passage of conical reamers and the intramedullary nail itself results in the distraction of intertrochanteric fragments with lateralization of the shaft from the femoral neck and varus malalignment. Here, we describe the mechanism by which this deformity is generated and describe techniques for preventing it, including the use of a modified starting point and an alternative to the conical opening reamers.
Medical subject headings
- Bone Malalignment
- Bone Nails
- Fracture Fixation, Intramedullary
- Hip Fractures
Anatomy
- femur
- hip