Continuous Infusion of Low-Dose Iohexol Measures Changing Glomerular Filtration Rate in Critically Ill Patients.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 29194145.
- Also identified by DOI 10.1097/CCM.0000000000002870.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Measurement of changing glomerular filtration rate in acute kidney injury remains problematic. We have previously used a continuous infusion of low-dose Iohexol to measure glomerular filtration rate in stable subjects and postulate that changes greater than 10.3% in critically ill patients indicate acute kidney injury. Our objective is to explore the extent to which continuous infusion of low-dose Iohexol can be a measure of changing glomerular filtration rate during acute kidney injury. Clinical observational exploratory study. Adult ICU. Three patient groups were recruited: nephrectomy group: predictable onset of acute kidney injury and outcome (n = 10); surgery group: predictable onset of acute kidney injury, unpredictable outcome (n = 11); and acute kidney injury group: unpredictable onset of acute kidney injury and outcome (n = 13). Continuous infusion of low-dose Iohexol was administered for 24-80 hours. Plasma (ClP) and renal (ClR) Iohexol clearances were measured at timed intervals. Kidney Disease: Improved Global Outcomes acute kidney injury criteria were fulfilled in 22 patients (nephrectomy = 5, surgery = 4, and acute kidney injury = 13); continuous infusion of low-dose Iohexol demonstrated acute kidney injury in 29 patients (nephrectomy = 10, surgery = 8, acute kidney injury = 11). Dynamic changes in glomerular filtration rate were tracked in all patients. In the nephrectomy group, ClR decreased by an expected 50% (50.8% ± 11.0%). Agreement between ClP and ClR improved with increasing duration of infusion: bias of ClP versus ClR at 48 hours was -0.1 ± 3.6 mL/min/1.73 m (limits of agreement: -7.2 to 7.1 mL/min/1.73 m). Coefficient of variation of laboratory sample analysis was 2.4%. Continuous infusion of low-dose Iohexol is accurate and precise when measuring glomerular filtration rate and tracks changes in patients with differing risks of acute kidney injury. Continuous infusion of low-dose Iohexol may provide a useful standard against which to test novel biomarkers for the diagnosis of acute kidney injury.
Medical subject headings
- Acute Kidney Injury
- Contrast Media
- Glomerular Filtration Rate
- Iohexol