The association of pre-operative home accelerometry with cardiopulmonary exercise variables.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 29230797.
- Also identified by DOI 10.1111/anae.14181.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We investigated the association of pre-operative activity, reported by the Duke Activity Score Index, Short Form-12 and measured by an accelerometer worn at home, with five cardiopulmonary exercise variables: peak power; peak oxygen consumption; anaerobic threshold; and ventilatory equivalents for oxygen and carbon dioxide. Fifty patients scheduled for major surgery underwent a standard pre-operative cardiopulmonary exercise test and wore a chest-mounted triaxial accelerometer for a mean (SD) duration of 3.2 (0.4) days. The Duke Activity Score Index and six accelerometer variables were significantly correlated with all five cardiopulmonary exercise variables, Pearson correlation coefficients 0.5-0.7, p = 0.02 to p < 0.001. Our results can guide future studies that measure physical activity for pre-operative assessment and interventions.
Medical subject headings
- Accelerometry
- Exercise
- Exercise Test