Previously unreported complications associated with integrated cage screws following anterior lumbar interbody fusion: report of 2 cases.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 29303470.
- Also identified by DOI 10.3171/2017.6.SPINE161443.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Anterior lumbar interbody fusion (ALIF) is a widely performed surgical treatment for various lumbar spine pathologies. The authors present the first reports of virtually identical cases of complications with integrated screws in stand-alone interbody cages. Two patients presented with the onset of S-1 radiculopathy due to screw misplacements following an ALIF procedure. In both cases, an integrated screw from the cage penetrated the dorsal aspect of the S-1 cortical margin of the vertebra, extended into the neural foramen, and injured the traversing left S-1 nerve roots. Advanced neuroimaging findings indicated nerve root impingement by the protruding screw tip. After substantial delays, radiculopathic symptoms were treated with removal of the offending instrumentation, aggressive posterior decompression of the bony and ligamentous structures, and posterolateral fusion surgery with pedicle screw fixation. Postoperative radiographic findings demonstrated decompression of the symptomatic nerve roots via removal of the extruded screw tips from the neural foramina.
Medical subject headings
- Bone Screws
- Lumbar Vertebrae
- Lumbosacral Region
- Postoperative Complications
Anatomy
- lumbar spine
- sacrum-coccyx