Concurrent Respiratory Motion Correction of Abdominal PET and Dynamic Contrast-Enhanced-MRI Using a Compressed Sensing Approach.
Where this comes from
- Record sourced from PubMed, PMID 29371404.
- Also identified by DOI 10.2967/jnumed.117.203943 and PMC identifier 6126447.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We present an approach for concurrent reconstruction of respiratory motion-compensated abdominal dynamic contrast-enhanced (DCE)-MRI and PET data in an integrated PET/MR scanner. The MR and PET reconstructions share the same motion vector fields derived from radial MR data; the approach is robust to changes in respiratory pattern and does not increase the total acquisition time. <b>Methods:</b> PET and DCE-MRI data of 12 oncologic patients were simultaneously acquired for 6 min on an integrated PET/MR system after administration of <sup>18</sup>F-FDG and gadoterate meglumine. Golden-angle radial MR data were continuously acquired simultaneously with PET data and sorted into multiple motion phases on the basis of a respiratory signal derived directly from the radial MR data. The resulting multidimensional dataset was reconstructed using a compressed sensing approach that exploits sparsity among respiratory phases. Motion vector fields obtained using the full 6-min (MC<sub>6-min</sub>) and only the last 1 min (MC<sub>1-min</sub>) of data were incorporated into the PET reconstruction to obtain motion-corrected PET images and in an MR iterative reconstruction algorithm to produce a series of motion-corrected DCE-MR images (moco_GRASP). The motion-correction methods (MC<sub>6-min</sub> and MC<sub>1-min</sub>) were evaluated by qualitative analysis of the MR images and quantitative analysis of SUV<sub>max</sub> and SUV<sub>mean</sub>, contrast, signal-to-noise ratio (SNR), and lesion volume in the PET images. <b>Results:</b> Motion-corrected MC<sub>6-min</sub> PET images demonstrated 30%, 23%, 34%, and 18% increases in average SUV<sub>max</sub>, SUV<sub>mean</sub>, contrast, and SNR and an average 40% reduction in lesion volume with respect to the non-motion-corrected PET images. The changes in these figures of merit were smaller but still substantial for the MC<sub>1-min</sub> protocol: 19%, 10%, 15%, and 9% increases in average SUV<sub>max</sub>, SUV<sub>mean</sub>, contrast, and SNR; and a 28% reduction in lesion volume. Moco_GRASP images were deemed of acceptable or better diagnostic image quality with respect to conventional breath-hold Cartesian volumetric interpolated breath-hold examination acquisitions. <b>Conclusion:</b> We presented a method that allows the simultaneous acquisition of respiratory motion-corrected diagnostic quality DCE-MRI and quantitatively accurate PET data in an integrated PET/MR scanner with negligible prolongation in acquisition time compared with routine PET/DCE-MRI protocols.
Medical subject headings
- Abdomen
- Contrast Media
- Image Processing, Computer-Assisted
- Magnetic Resonance Imaging
- Movement
- Positron-Emission Tomography
- Respiration