Concentric electrodes improve microfluidic droplet sorting.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 29383336.
- Also identified by DOI 10.1039/c7lc01242j and PMC identifier 6105269.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Microfluidic droplet sorting allows selection of subpopulations of cells, nucleic acids, and biomolecules with soluble assays. Dielectrophoresis is widely used for sorting because it generates strong forces on droplets, actuates rapidly, and is easy to integrate into microfluidic chips. However, existing device designs apply a short force, limiting the deflection of droplets, and therefore the speed and reliability of sorting. We describe a concentric design that applies a long force, allowing large deflections and increased reliability. We demonstrate the utility of this design by sorting polydisperse emulsions, which are typically difficult to sort with high purity.