Intraoperative monitoring of marginal mandibular nerve during neck dissection.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 29389042.
- Also identified by DOI 10.1002/hed.25078.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to assess the efficacy of intraoperative nerve integrity monitoring (NIM) to prevent marginal mandibular nerve injuries during neck dissection. This prospective study compared 36 patients undergoing NIM-assisted neck dissection from July 2014 to March 2015 to a cohort of 35 patients subjected to neck dissection over an identical period of time before the technique was introduced. We also assessed possible correlations between marginal mandibular nerve injuries and other factors, such as anthropometric measurements, presence of clinical neck metastases, type of neck dissection, and site of primary tumor. The incidence of marginal mandibular nerve paralyses was significantly lower among the group of patients undergoing NIM-assisted neck dissection (P = .021). There was no significant difference in the duration of the procedure, and the technique resulted in a limited increase of cost. No other factor seemed to influence the onset of marginal mandibular nerve palsy. In our opinion, NIM is a valuable aid for preventing marginal mandibular nerve injuries during neck dissection.
Medical subject headings
- Head and Neck Neoplasms
- Intraoperative Complications
- Intraoperative Neurophysiological Monitoring
- Mandibular Nerve
- Neck Dissection
- Trigeminal Nerve Injuries