Safety and Effectiveness of Second-Generation Drug-Eluting Stents in Patients With Left Main Coronary Artery Disease.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 29471933.
- Also identified by DOI 10.1016/j.jacc.2017.12.032.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Limited data are available on the relative performances between different types of drug-eluting stents (DES) for obstructive left main coronary artery disease (LMCAD). This study sought to compare effectiveness and safety profiles of various second-generation DES for LMCAD in real-world clinical practice. Among 4,470 patients in 3, multicenter, prospective registries (IRIS-DES [Interventional Cardiology Research Incorporation Society-Drug-Eluting Stents] registry, the IRIS-MAIN [Interventional Cardiology Research Incorporation Society-Left MAIN Revascularization] registry, and the PRECOMBAT [PREmier of Randomized COMparison of Bypass Surgery versus AngioplasTy Using Drug-Eluting Stent in Patients with Left Main Coronary Artery Disease] study) treated between July 2007 and July 2015, the authors identified 2,692 patients with significant LMCAD who received second-generation DES; 1,254 with cobalt-chromium everolimus-eluting stents (CoCr-EES), 232 with biodegradable polymer biolimus-eluting stents (BP-BES), 616 with platinum-chromium EES (PtCr-EES), and 590 with Resolute zotarolimus-eluting stent (Re-ZES). The primary outcome was target-vessel failure. The observed 3-year rates of target-vessel failure were not significantly different for the different types of DES (16.7% for the CoCr-EES, 13.2% for the BP-BES, 18.7% for the PtCr-EES, and 14.7% for the Re-ZES; p = 0.15). In multiple treatment propensity score analysis, the adjusted hazard ratios (HRs) for target-vessel failure were similar in between-group comparisons of the different DES, except for the PtCr-EES versus the BP-BES (reference; HR: 1.60; 95% confidence interval: 1.01 to 2.54; p = 0.046). There were no significant differences in risk of composite of all-cause death, any myocardial infarction, or any revascularization and its individual components according to the different types of DES. Although the 3-year incidence of stent thrombosis was considerably low (≤1.0%) for all types of DES, between-group differences were observed, generally favoring the EES platforms. In this pooled analysis of 3 prospective registries involving unrestricted use of various second-generation DES for LMCAD, we found no significant between-group differences in 3-year risk of target-vessel failure, except for a higher risk of primary outcome with PtCr-EES compared to BP-BES. (Evaluation of the First, Second, and New Drug-Eluting Stents in Routine Clinical Practice [IRIS-DES]; NCT01186133).
Medical subject headings
- Coronary Artery Disease
- Drug-Eluting Stents
- Patient Safety
- Registries