Complications of Radial Column Plating of the Distal Radius.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 29484901.
- Also identified by DOI 10.1177/1558944718760861 and PMC identifier 6759978.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
<b>Background:</b> Distal radius fractures treated with open reduction and internal fixation are commonly stabilized with a volar locking plate; however, more complex fracture patterns may require supplemental fixation with fragment-specific implants. The objective of this study was to evaluate the outcomes of distal radius fractures treated with radial column plates. <b>Methods:</b> A consecutive series of 61 patients who sustained distal radius fractures underwent radial column plating alone or in conjunction with other implants between August 2006 and January 2014. Thirty-one patients returned for follow-up or returned a mailed questionnaire at an average of 4.1 years. The outcomes measures included Visual Analog Scale (VAS); Disabilities of the Arm, Shoulder and Hand (DASH); and Patient-Rated Wrist Evaluation (PRWE) scores. <b>Results:</b> Sixty-one patients with a mean age of 55 years (range, 20-87) met inclusion criteria and were available for follow-up or chart review at an average of 5.2 years (range, 1.6-9.0 years). Seventeen of 61 (28%) underwent radial column plate removal. Twenty patients returned for final follow-up examination, and 11 completed questionnaires via mail. Subjective scores included a mean postoperative VAS of 0.72, DASH score of 17.2, and PRWE score of 15.7. Hardware sensitivity and wrist stiffness were the most common complications at final follow-up. <b>Conclusions:</b> Radial column plating of the distal radius is a safe treatment modality and a valuable adjunct in the setting of complex distal radius fractures, but patients should be counseled that there is a 28% chance that hardware removal may be required. Our retrospective review found evidence of few complications and objective scores consistent with return to normal function.
Medical subject headings
- Bone Plates
- Fracture Fixation, Internal
- Open Fracture Reduction
- Radius
- Radius Fractures
Anatomy
- radius
- wrist