Gd-EOB-DTPA-enhanced T1 relaxometry for assessment of liver function determined by real-time <sup>13</sup>C-methacetin breath test.

Haimerl, Michael; Fuhrmann, Irene; Poelsterl, Stefanie; Fellner, Claudia; Nickel, Marcel D; Weigand, Kilian; Dahlke, Marc H; Verloh, Niklas et al. · Eur Radiol · 2018

prospective_cohort · Level II

Where this comes from

Abstract

To determine whether liver function as determined by intravenous administration of <sup>13</sup>C-methacetin and continuous real-time breath analysis can be estimated quantitatively from gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance (MR) relaxometry. Sixty-six patients underwent a <sup>13</sup>C-methacetin breath test (<sup>13</sup>C-MBT) for evaluation of liver function and Gd-EOB-DTPA-enhanced T1-relaxometry at 3 T. A transverse 3D VIBE sequence with an inline T1 calculation based on variable flip angles was acquired prior to (T1 pre) and 20 min post-Gd-EOB-DTPA (T1 post) administration. The reduction rate of T1 relaxation time (rrT1) and T1 relaxation velocity index (∆R1) between pre- and post-contrast images was evaluated. <sup>13</sup>C-MBT values were correlated with T1<sub>post</sub>, ∆R1 and rrT1, providing an MRI-based estimated <sup>13</sup>C-MBT value. The interobserver reliability was assessed by determining the intraclass correlation coefficient (ICC). Stratified by three different categories of <sup>13</sup>C-MBT readouts, there was a constant increase of T1 post with increasing progression of diminished liver function (p ≤ 0.030) and a constant significant decrease of ∆R1 (p ≤ 0.025) and rrT1 (p < 0.018) with progression of liver damage as assessed by <sup>13</sup>C-methacetin breath analysis. ICC for all T1 relaxation values and indices was excellent (> 0.88). A simple regression model showed a log-linear correlation of <sup>13</sup>C-MBT values with T1<sub>post</sub> (r = 0.57; p < 0.001), ∆R1 (r = 0.59; p < 0.001) and rrT1 (r = 0.70; p < 0.001). Liver function as determined using real-time <sup>13</sup>C-methacetin breath analysis can be estimated quantitatively from Gd-EOB-DTPA-enhanced MR relaxometry. • Gd-EOB-DTPA-enhanced T1 relaxometry quantifies liver function • Gd-EOB-DTPA-enhanced MR relaxometry may provide parameters for assessing liver function before surgery • Gd-EOB-DTPA-enhanced MR relaxometry may be useful for monitoring liver disease progression • Gd-EOB-DTPA-enhanced MR relaxometry has the potential to become a novel liver function index.

Medical subject headings