Day-and-Night Closed-Loop Insulin Delivery in a Broad Population of Pregnant Women With Type 1 Diabetes: A Randomized Controlled Crossover Trial.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 29535135.
- Also identified by DOI 10.2337/dc17-2534.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Despite advances in technology, optimal glucose control remains elusive and neonatal complications remain ubiquitous in type 1 diabetes (T1D) pregnancy. Our aim was to examine the safety, efficacy, and longer-term feasibility of day-and-night closed-loop insulin delivery. We recruited 16 pregnant women (mean [SD]: age 32.8 [5.0] years, T1D duration 19.4 [10.2] years, HbA<sub>1c</sub> 8.0% [1.1], and BMI 26.6 [4.4] kg/m<sup>2</sup>) to an open-label, randomized, crossover trial. Participants completed 28 days of closed-loop and sensor-augmented pump (SAP) insulin delivery separated by a washout period. Afterward, participants could continue to use the closed-loop system up to 6 weeks postpartum. The primary end point was the proportion of time with glucose levels within the target range (63-140 mg/dL). The proportion of time with glucose levels within target was comparable during closed-loop and SAP insulin delivery (62.3 vs. 60.1% [95% CI -4.1 to 8.3]; <i>P</i> = 0.47). Mean glucose and time spent hyperglycemic >140 mg/dL also did not differ (131.4 vs. 131.4 mg/dL [<i>P</i> = 0.85] and 36.6 vs. 36.1% [<i>P</i> = 0.86], respectively). During closed-loop, fewer hypoglycemic episodes occurred (median 8 [range 1-17] vs. 12.5 [1-53] over 28 days; <i>P</i> = 0.04) and less time at <63 mg/dL (1.6 vs. 2.7%; <i>P</i> = 0.02). Hypoglycemia <50 mg/dL (0.24 vs. 0.47%; <i>P</i> = 0.03) and low blood glucose index (1.0 vs. 1.4; <i>P</i> = 0.01) were lower. Less nocturnal hypoglycemia (2300-0700 h) during closed-loop therapy (1.1 vs. 2.7%; <i>P</i> = 0.008) and a trend toward higher overnight time in target (67.7 vs. 60.6%; <i>P</i> = 0.06) were found. Closed-loop insulin delivery was associated with comparable glucose control and significantly less hypoglycemia than SAP therapy. Larger, longer-duration multicenter trials are now indicated to determine clinical efficacy of closed-loop insulin delivery in T1D pregnancy and the impact on neonatal outcomes.
Medical subject headings
- Diabetes Mellitus, Type 1
- Hypoglycemic Agents
- Insulin
- Insulin Infusion Systems
- Pregnancy in Diabetics