Effect and impact of mechanical ventilation in myotonic dystrophy type 1: a prospective cohort study.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 29572271.
- Also identified by DOI 10.1136/thoraxjnl-2017-210610.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Few studies have assessed the impact of home ventilation in patients with myotonic dystrophy type 1 (DM1) and no specific recommendations are available. We assessed the survival associated with category of home ventilation adherence of patients with DM1 followed up at a home ventilation unit using a Cox proportional hazards model. 218 patients were included; those who refused or delayed their acceptance of non-invasive ventilation were at higher risk for severe events (invasive ventilation or death) (P=0.03). Risk of death was associated with orthopnoea (HR 2.37; 95% CI 1.17 to 4.80; P<0.02) and adherence category (100 to 90% vs >75%: HR 3.26; 95% CI 1.32 to 8.04; P<0.03). Failure to use home ventilation as prescribed may be associated with increased mortality in patients with DM1.
Medical subject headings
- Myotonic Dystrophy
- Patient Compliance
- Respiration, Artificial
- Respiratory Insufficiency