Accuracy of Pulse Oximetry Screening for Critical Congenital Heart Defects after Home Birth and Early Postnatal Discharge.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 29580679.
- Also identified by DOI 10.1016/j.jpeds.2018.01.039.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To assess the accuracy of pulse oximetry screening for critical congenital heart defects (CCHDs) in a setting with home births and early discharge after hospital deliveries, by using an adapted protocol fitting the work patterns of community midwives. Pre- and postductal oxygen saturations (SpO<sub>2</sub>) were measured ≥1 hour after birth and on day 2 or 3. Screenings were positive if the SpO<sub>2</sub> measurement was <90% or if 2 independent measures of pre- and postductal SpO<sub>2</sub> were <95% and/or the pre-/postductal difference was >3%. Positive screenings were referred for pediatric assessment. Primary outcomes were sensitivity, specificity, and false-positive rate of pulse oximetry screening for CCHD. Secondary outcome was detection of noncardiac illnesses. The prenatal detection rate of CCHDs was 73%. After we excluded these cases and symptomatic CCHDs presenting immediately after birth, 23 959 newborns were screened. Pulse oximetry screening sensitivity in the remaining cohort was 50.0% (95% CI 23.7-76.3) and specificity was 99.1% (95% CI 99.0-99.2). Pulse oximetry screening was false positive for CCHDs in 221 infants, of whom 61% (134) had noncardiac illnesses, including infections (31) and respiratory pathology (88). Pulse oximetry screening did not detect left-heart obstructive CCHDs. Including cases with prenatally detected CCHDs increased the sensitivity to 70.2% (95% CI 56.0-81.4). Pulse oximetry screening adapted for perinatal care in home births and early postdelivery hospital discharge assisted the diagnosis of CCHDs before signs of cardiovascular collapse. High prenatal detection led to a moderate sensitivity of pulse oximetry screening. The screening also detected noncardiac illnesses in 0.6% of all infants, including infections and respiratory morbidity, which led to early recognition and referral for treatment.
Medical subject headings
- Heart Defects, Congenital
- Neonatal Screening
- Oximetry