Graphical and statistical analyses of the oculocardiac reflex during a non-invasive intracranial pressure measurement.

Hamarat, Yasin; Bartusis, Laimonas; Deimantavicius, Mantas; Siaudvytyte, Lina; Januleviciene, Ingrida; Ragauskas, Arminas; Bershad, Eric M; Fandino, Javier et al. · PLoS One · 2018

retrospective_cohort · Level III

Where this comes from

Abstract

This study aimed to examine the incidence of the oculocardiac reflex during a non-invasive intracranial pressure measurement when gradual external pressure was applied to the orbital tissues and eye. Patients (n = 101) and healthy volunteers (n = 56) aged 20-75 years who underwent a non-invasive intracranial pressure measurement were included in this retrospective oculocardiac reflex analysis. Prespecified thresholds greater than a 10% or 20% decrease in the heart rate from baseline were used to determine the incidence of the oculocardiac reflex. None of the subjects had a greater than 20% decrease in heart rate from baseline. Four subjects had a greater than 10% decrease in heart rate from baseline, representing 0.9% of the total pressure steps. Three of these subjects were healthy volunteers, and one was a glaucoma patient. The incidence of the oculocardiac reflex during a non-invasive intracranial pressure measurement procedure was very low and not associated with any clinically relevant effects.

Medical subject headings