Graphical and statistical analyses of the oculocardiac reflex during a non-invasive intracranial pressure measurement.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 29672564.
- Also identified by DOI 10.1371/journal.pone.0196155 and PMC identifier 5909620.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study aimed to examine the incidence of the oculocardiac reflex during a non-invasive intracranial pressure measurement when gradual external pressure was applied to the orbital tissues and eye. Patients (n = 101) and healthy volunteers (n = 56) aged 20-75 years who underwent a non-invasive intracranial pressure measurement were included in this retrospective oculocardiac reflex analysis. Prespecified thresholds greater than a 10% or 20% decrease in the heart rate from baseline were used to determine the incidence of the oculocardiac reflex. None of the subjects had a greater than 20% decrease in heart rate from baseline. Four subjects had a greater than 10% decrease in heart rate from baseline, representing 0.9% of the total pressure steps. Three of these subjects were healthy volunteers, and one was a glaucoma patient. The incidence of the oculocardiac reflex during a non-invasive intracranial pressure measurement procedure was very low and not associated with any clinically relevant effects.
Medical subject headings
- Diagnostic Techniques and Procedures
- Intracranial Pressure
- Models, Statistical
- Reflex, Oculocardiac