Cement mantle thickness does not influence serum or local gentamicin concentrations in hybrid total hip arthroplasty: a randomised controlled trial.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 29734817.
- Also identified by DOI 10.1177/1120700018767335.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We investigated the in vivo gentamicin elution kinetics of Hi-Fatigue Gentamicin Bone Cement (AAP Biomaterials GmbH) in serum and drain fluid after hybrid hip arthroplasty and the relationship with cement mantle thickness. We compared in a randomised, non-blinded prospective study, the local and systemic gentamicin concentrations in 2 groups. The thin cement mantle group ( n = 16) received a stem implanted line-to-line with the broach, whereas the thick group ( n = 14) had an undersized stem. Gentamicin concentrations were measured in drain fluid and serum at set intervals for 3 days postoperatively. In both groups, local gentamicin concentrations were similar. After a high initial burst above the minimal inhibitory concentration (thin: 57.2 mg/L (SD 34.4), thick: 54.9 mg/L (SD 19.9), p = 0.823) local gentamicin concentrations declined rapidly. In both groups, serum concentrations never exceeded toxic levels (maximum 1.08 mg/L). In hybrid total hip arthroplasty, Hi-Fatigue Gentamicin Bone Cement resulted in effective and safe gentamicin concentrations. Clinical trial protocol number: PMCI 12/02.
Medical subject headings
- Anti-Bacterial Agents
- Arthroplasty, Replacement, Hip
- Bone Cements
- Gentamicins
- Osteoarthritis, Hip
Anatomy
- hip