The V-Shaped Distal Triceps Tendon Repair: A Comparative Biomechanical Analysis.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 29763339.
- Also identified by DOI 10.1177/0363546518771359.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Restoring footprint anatomy, minimizing gap formation, and maximizing the strength of distal triceps tendon repairs are essential factors for a successful healing process and return to sport. The novel V-shaped distal triceps tendon repair technique with unicortical button fixation closely restores footprint anatomy, provides minimal gap formation and high ultimate failure load, and minimizes iatrogenic fracture risk in acute/subacute distal triceps tendon tears. Controlled laboratory study. Twenty-four cadaveric elbows (mean ± SD age, 66 ± 5 years) were randomly assigned to 1 of 3 repair groups: the transosseous cruciate repair technique (gold standard), the knotless suture-bridge repair technique, and the V-shaped distal triceps tendon repair technique. Anatomic measurements of the central triceps tendon footprint were obtained in all specimens with a 3-dimensional digitizer before and after the repair. Cyclic loading was performed for a total of 1500 cycles at a rate of 0.25 Hz, pulling in the direction of the triceps. Displacements were measured on the medial and lateral tendon sites with 2 differential variable reluctance transducers. Load to failure and construct failure mode were recorded. The mean triceps bony insertion area was 399.05 ± 81.23 mm<sup>2</sup>. The transosseous cruciate repair technique restored 36.6% ± 16.8% of the native tendon insertion area, which was significantly different when compared with the knotless suture-bridge repair technique (85.2% ± 14.8%, P = .001) and the V-shaped distal triceps tendon repair technique (88.9% ± 14.8%, P = .002). Mean displacement showed no significant difference between the V-shaped distal triceps tendon repair technique (medial side, 0.75 ± 0.56 mm; lateral side, 0.99 ± 0.59 mm) and the knotless suture-bridge repair technique (1.61 ± 0.97 mm and 1.29 ± 0.8 mm) but significance between the V-shaped distal triceps tendon repair technique and the transosseous cruciate repair technique (4.91 ± 1.12 mm and 5.78 ± 0.9 mm, P < .001). Mean peak failure load of the V-shaped distal triceps tendon repair technique (732.1 ± 156.0 N) was significantly higher than that of the knotless suture-bridge repair technique (505.4 ± 173.9 N, P = .011) and the transosseous cruciate repair technique (281.1 ± 74.8 N, P < .001). Mechanism of failure differed among the 3 repairs, with the only olecranon fracture occurring in the knotless suture-bridge repair technique at the level of the lateral row suture anchors. At time zero, the V-shaped distal triceps tendon repair technique and the knotless suture-bridge repair technique both provided anatomic footprint coverage. Ultimate load to failure was highest for the V-shaped distal triceps tendon repair technique, while gap formation was different only in comparison with the transosseous cruciate repair technique. The V-shaped distal triceps tendon repair technique provides an alternative procedure to other established repairs for acute/subacute distal triceps tendon ruptures. The reduced repair site motion of the V-shaped distal triceps tendon repair technique and the knotless suture-bridge repair technique at the time of surgery may allow a more aggressive rehabilitation program in the early postoperative period.
Medical subject headings
- Arthroplasty
- Elbow Joint
- Tendon Injuries
Anatomy
- elbow