Mortality in adult patients with fluid overload evaluated by BIVA upon admission to the emergency department.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 29925520.
- Also identified by DOI 10.1136/postgradmedj-2018-135695.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this study was to investigate the association of fluid overload, measured by bioelectrical impedance vector analysis (BIVA) and also by accumulated fluid balance, with 30-day mortality rates in patients admitted to the emergency department (ED). We conducted a prospective observational study of fluid overload using BIVA, taking measures using a multiple-frequency whole-body tetrapolar equipment. Accumulated fluid balances were obtained at 24, 48 and 72 hours from ED admission and its association with 30-day mortality. 109 patients admitted to the ED classified as fluid overloaded by both methods. According to BIVA, 71.6% (n=78) of patients had fluid overload on ED admission. These patients were older and had higher Sequential Organ Failure Assessment scores. During a median follow-up period of 30 days, 32.1% (n=25) of patients with fluid overload evaluated by BIVA died versus none with normovolaemia (p=0.001). There was no statistically significant difference in mortality between patients with and without fluid overload as assessed by accumulated fluid balance (p=0.81). Fluid overload on admission evaluated by BIVA was significantly related to mortality in patients admitted to the ED.
Medical subject headings
- Critical Illness
- Electric Impedance
- Heart Failure