A usability and safety analysis of electronic health records: a multi-center study.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 29982549.
- Also identified by DOI 10.1093/jamia/ocy088 and PMC identifier 7646875.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To characterize the variability in usability and safety of EHRs from two vendors across four healthcare systems (2 Epic and 2 Cerner). Twelve to 15 emergency medicine physicians participated from each site and completed six clinical scenarios. Keystroke, mouse click, and video data were collected. From the six scenarios, two diagnostic imaging, laboratory, and medication tasks were analyzed. There was wide variability in task completion time, clicks, and error rates. For certain tasks, there were an average of a nine-fold difference in time and eight-fold difference in clicks. Error rates varied by task (X-ray 16.7% to 25%, MRI: 0 to 10%, Lactate: 0% to 14.3%, Tylenol: 0 to 30%; Taper: 16.7% to 50%). The variability in time, clicks, and error rates highlights the need for improved implementation optimization. EHR implementation, in addition to vendor design and development, is critical to usable and safe products.
Medical subject headings
- Medical Errors
- Medical Records Systems, Computerized
- Task Performance and Analysis