Volar plating in distal radius fractures: A prospective clinical study on efficacy of dorsal tangential views to avoid screw penetration.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 30017179.
- Also identified by DOI 10.1016/j.injury.2018.06.023.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this prospective cohort study of patients treated with volar plating for distal radius fractures is to evaluate the efficacy (defined as detection rate, or the ability to detect dorsally protruding screws) of additional dorsal tangential views (DTV) after obtaining standard anteroposterior (AP) and elevated lateral views by evaluating the change in intraoperative strategy in 100 patients. 100 patients aged 18 years and older undergoing volar plating for acute extra- or intra- articular distal radius fractures were prospectively enrolled. Intraoperative fluoroscopy views, including AP, elevated lateral and DTV were obtained. Intraoperative -screw- revision frequency for dorsal screw protrusion, screw position relative to volar plate and to dorsal compartment, and screw lengths were evaluated. Additional DTV led to a change of intraoperative management in 31 of 100 (31%) of patients. A total of 35 out of 504 screws (6.9%) were changed. Screws in the two most radial screws in the plate were at the highest risk of being revised; 16 (46%) screws in most radial position and nine (26%) screws in the 2nd from radial position were revised. Furthermore, five (14%) screws in both the 2nd from ulnar and most ulnar screw holes were revised after DTV. No screws were revised in the central hole. The median length of revised protruding screws was 22 mm (range, 12-26 mm), and these were changed to a mean length of 20 mm (range, 10-22 mm). In this prospective series of 100 patients, obtaining additional DTV is found to be efficacious as it led to change in intraoperative strategy in one-third of patients. We concur with previous pilot studies that DTV, after obtaining conventional AP and elevated lateral views, is advised to avoid dorsally protruding screws, which could minimise the potential for iatrogenic extensor tendon rupture after volar plating for distal radius fractures. Diagnostic accuracy of DTV is subject of a subsequent prospective cohort study with post-operative CT to serve as the reference standard. .Prognostic I.
Medical subject headings
- Bone Plates
- Bone Screws
- Fracture Fixation, Internal
- Radius Fractures