Overhang molecular beacons encapsulated in tethered cationic lipoplex nanoparticles for detection of single-point mutation in extracellular vesicle-associated RNAs.

Hu, Jiaming; Kwak, Kwang Joo; Shi, Junfeng; Yu, Bohao; Sheng, Yan; Lee, Ly James · Biomaterials · 2018

basic_science · Level V

Where this comes from

Abstract

Detection of specific extracellular RNAs has been developed for non-invasive cancer diagnosis. However, accurate and efficient identification of RNAs with single-point mutation in cancer cells-derived extracellular vesicles (EVs) is challenging. Herein, we present a unique overhang molecular beacon with internal dye (Ohi-MB) with a stable hairpin structure, fast hybridization kinetics and single mismatch specificity. Ohi-MBs are encapsulated in cationic lipoplex nanoparticles (CLNs) that are tethered on a gold coated glass slide as a chip, which can capture circulating EVs and detect encapsulated target RNAs in-situ in a single step. The capability of detection of single-point mutation by CLN-Ohi-MB is demonstrated in artificial EVs and cancer cells. This CLN-Ohi-MB biochip could quantify single-point mutations in KRAS mRNA (G12C, G12D, G12V) in pancreatic cancer cell-derived EVs and single-point mutations in EGFR mRNA (L858R and T790M) in lung cancer cell-derived EVs with high specificity, not achievable by conventional molecular probes. We show that CLN-Ohi-MB biochip could selectively and sensitively identify single-point mutations in KRAS mRNA in human serum EVs, distinguishing pancreatic cancer patients with different mutations.

Medical subject headings