Dixon-VIBE Deep Learning (DIVIDE) Pseudo-CT Synthesis for Pelvis PET/MR Attenuation Correction.

Torrado-Carvajal, Angel; Vera-Olmos, Javier; Izquierdo-Garcia, David; Catalano, Onofrio A; Morales, Manuel A; Margolin, Justin; Soricelli, Andrea; Salvatore, Marco et al. · J Nucl Med · 2019

Where this comes from

Abstract

Whole-body attenuation correction (AC) is still challenging in combined PET/MR scanners. We describe Dixon-VIBE Deep Learning (DIVIDE), a deep-learning network that allows synthesizing pelvis pseudo-CT maps based only on the standard Dixon volumetric interpolated breath-hold examination (Dixon-VIBE) images currently acquired for AC in some commercial scanners. <b>Methods:</b> We propose a network that maps between the four 2-dimensional (2D) Dixon MR images (water, fat, in-phase, and out-of-phase) and their corresponding 2D CT image. In contrast to previous methods, we used transposed convolutions to learn the up-sampling parameters, we used whole 2D slices to provide context information, and we pretrained the network with brain images. Twenty-eight datasets obtained from 19 patients who underwent PET/CT and PET/MR examinations were used to evaluate the proposed method. We assessed the accuracy of the μ-maps and reconstructed PET images by performing voxel- and region-based analysis comparing the SUVs (in g/mL) obtained after AC using the Dixon-VIBE (PET<sub>Dixon</sub>), DIVIDE (PET<sub>DIVIDE</sub>), and CT-based (PET<sub>CT</sub>) methods. Additionally, the bias in quantification was estimated in synthetic lesions defined in the prostate, rectum, pelvis, and spine. <b>Results:</b> Absolute mean relative change values relative to CT AC were lower than 2% on average for the DIVIDE method in every region of interest except for bone tissue, where it was lower than 4% and 6.75 times smaller than the relative change of the Dixon method. There was an excellent voxel-by-voxel correlation between PET<sub>CT</sub> and PET<sub>DIVIDE</sub> (<i>R</i><sup>2</sup> = 0.9998, <i>P</i> < 0.01). The Bland-Altman plot between PET<sub>CT</sub> and PET<sub>DIVIDE</sub> showed that the average of the differences and the variability were lower (mean PET<sub>CT</sub>-PET<sub>DIVIDE</sub> SUV, 0.0003; PET<sub>CT</sub>-PET<sub>DIVIDE</sub> SD, 0.0094; 95% confidence interval, [-0.0180,0.0188]) than the average of differences between PET<sub>CT</sub> and PET<sub>Dixon</sub> (mean PET<sub>CT</sub>-PET<sub>Dixon</sub> SUV, 0.0006; PET<sub>CT</sub>-PET<sub>Dixon</sub> SD, 0.0264; 95% confidence interval, [-0.0510,0.0524]). Statistically significant changes in PET data quantification were observed between the 2 methods in the synthetic lesions, with the largest improvement in femur and spine lesions. <b>Conclusion:</b> The DIVIDE method can accurately synthesize a pelvis pseudo-CT scan from standard Dixon-VIBE images, allowing for accurate AC in combined PET/MR scanners. Additionally, our implementation allows rapid pseudo-CT synthesis, making it suitable for routine applications and even allowing retrospective processing of Dixon-VIBE data.

Medical subject headings