Automated O<sub>2</sub> titration improves exercise capacity in patients with hypercapnic chronic obstructive pulmonary disease: a randomised controlled cross-over trial.

Vivodtzev, Isabelle; L'Her, Erwan; Vottero, Gabrielle; Yankoff, Claire; Tamisier, Renaud; Maltais, François; Lellouche, François; Pépin, Jean-Louis · Thorax · 2019

rct · Level II

Where this comes from

Abstract

Automatically titrated O<sub>2</sub> flows (FreeO<sub>2</sub>) was compared with constant O<sub>2</sub> flow on exercise capacity, O<sub>2</sub> saturation and risk of hyperoxia-related hypercapnia in patients with severe COPD with baseline hypercapnia and long-term oxygen therapy (LTOT). Twelve patients were enrolled in a randomised double-blind cross-over study to perform exercise with either FreeO<sub>2</sub> or constant flow. Endurance time (primary outcome) and SpO<sub>2</sub> were both significantly improved with FreeO<sub>2</sub>compared with constant flow (p<0.04), although pCO<sub>2</sub> was similar in both conditions. Automated titration of O<sub>2</sub> significantly and clinically improved endurance walking time in patients with severe COPD receiving LTOT, without worsening of pCO<sub>2</sub> TRIAL REGISTRATION NUMBER: Results , NCT01575327.