Effectiveness of small monitoring skin paddle in free muscle flap for scalp reconstruction.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 30175898.
- Also identified by DOI 10.1002/hed.25347.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Monitoring free muscle flaps with skin grafts is difficult. To intensify the monitoring process for this type of flap, a small skin paddle was included in the flap and analyzed its effects. A retrospective analysis of all patients who underwent scalp reconstruction with a free latissimus dorsi flap and skin graft between 1994 and 2016 was conducted. Flap monitoring was proceeded using a combination of clinical examination and handheld Doppler for both types of flaps. A total of 71 patients were included in this study and were divided into a study group (skin paddle included; n = 30) and a control group (conventional method; n = 41). The time between initial surgery to pedicle exploration was significantly shorter in the study group (11.3 ± 2.5 vs 79.8 ± 42.6 hours; P = .024). The flap salvage rate was significantly higher in the study group (100% vs 16.7%; P = .048). The efficacy of flap monitoring and flap salvage outcomes were improved by including a small monitoring skin flap.
Medical subject headings
- Free Tissue Flaps
- Graft Rejection
- Monitoring, Physiologic
- Plastic Surgery Procedures
- Scalp
- Skin Transplantation