Three-Hour Delayed Imaging Improves Assessment of Coronary <sup>18</sup>F-Sodium Fluoride PET.

Kwiecinski, Jacek; Berman, Daniel S; Lee, Sang-Eun; Dey, Damini; Cadet, Sebastien; Lassen, Martin L; Germano, Guido; Jansen, Maurits A et al. · J Nucl Med · 2019

Where this comes from

Abstract

Coronary <sup>18</sup>F-sodium fluoride (<sup>18</sup>F-NaF) PET identifies ruptured plaques in patients with recent myocardial infarction and localizes to atherosclerotic lesions with active calcification. Most studies to date have performed the PET acquisition 1 h after injection. Although qualitative and semiquantitative analysis is feasible with 1-h images, residual blood-pool activity often makes it difficult to discriminate plaques with <sup>18</sup>F-NaF uptake from noise. We aimed to assess whether delayed PET performed 3 h after injection improves image quality and uptake measurements. <b>Methods:</b> Twenty patients (67 ± 7 y old, 55% male) with stable coronary artery disease underwent coronary CT angiography (CTA) and PET/CT both 1 h and 3 h after the injection of 266.2 ± 13.3 MBq of <sup>18</sup>F-NaF. We compared the visual pattern of coronary uptake, maximal background (blood pool) activity, noise, SUV<sub>max</sub>, corrected SUV<sub>max</sub> (cSUV<sub>max</sub>), and target-to-background (TBR) ratio in lesions defined by CTA on 1-h versus 3-h <sup>18</sup>F-NaF PET. <b>Results:</b> On 1-h PET, 26 CTA lesions with <sup>18</sup>F-NaF PET uptake were identified in 12 (60%) patients. On 3-h PET, we detected <sup>18</sup>F-NaF PET uptake in 7 lesions that were not identified on 1-h PET. The median cSUV<sub>max</sub> and TBRs of these lesions were 0.48 (interquartile range [IQR], 0.44-0.51) and 1.45 (IQR, 1.39-1.52), respectively, compared with -0.01 (IQR, -0.03-0.001) and 0.95 (IQR, 0.90-0.98), respectively, on 1-h PET (both <i>P</i> < 0.001). Across the entire cohort, 3-h PET SUV<sub>max</sub> was similar to 1-h PET measurements (1.63 [IQR, 1.37-1.98] vs. 1.55 [IQR, 1.43-1.89], <i>P</i> = 0.30), and the background activity was lower (0.71 [IQR, 0.65-0.81] vs. 1.24 [IQR, 1.05-1.31], <i>P</i> < 0.001). On 3-h PET, TBR, cSUV<sub>max</sub>, and noise were significantly higher (respectively: 2.30 [IQR, 1.70-2.68] vs. 1.28 [IQR, 0.98-1.56], <i>P</i> < 0.001; 0.38 [IQR, 0.27-0.70] vs. 0.90 [IQR, 0.64-1.17], <i>P</i> < 0.001; and 0.10 [IQR, 0.09-0.12] vs. 0.07 [IQR, 0.06-0.09], <i>P</i> = 0.02). Median cSUV<sub>max</sub> and TBR increased by 92% (range, 33%-225%) and 80% (range, 20%-177%), respectively. <b>Conclusion:</b> Blood-pool activity decreases on delayed imaging, facilitating the assessment of <sup>18</sup>F-NaF uptake in coronary plaques. Median TBR increases by 80%, leading to the detection of more plaques with significant uptake than are detected using the standard 1-h protocol. A greater than 1-h delay may improve the detection of <sup>18</sup>F-NaF uptake in coronary artery plaques.

Medical subject headings