Evaluation of the quality of cardiopulmonary resuscitation according to vehicle driving pattern, using a virtual reality ambulance driving system: a prospective, cross-over, randomised study.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 30269076.
- Also identified by DOI 10.1136/bmjopen-2018-023784 and PMC identifier 6169751.
- Licence recorded as CC BY-NC.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To analyse changes in the quality of cardiopulmonary resuscitation (CPR) according to driving patterns encountered during ambulance transport, using a virtual reality simulator. Prospective, cross-over, randomised study. This study was conducted at the National Fire Service Academy, Cheonan-si, Korea. Emergency medical technicians (39 men and 9 women) attending the National Fire Service Academy for clinical training with ≥6 months field experience or having performed ≥10 CPR. Individuals who withdrew consent were excluded. CPR quality parameters (eg, chest compression depth and its variability). Chest compressions were performed for 8 min each in a stationary and driving state. The mean chest compression depths were 54.8 mm and 55.3 mm during these two states, respectively (p=0.41). The SD of the chest compression depth was significantly higher while in the driving (7.6 mm) than in the stationary state (6.5 mm; p=0.04). The compression depths in the speed bump and sudden stop sections were 51.5 mm and 50.6 mm, respectively, which was shallower than those in all other sections (p<0.001). The correct hand position rate was low in the speed bump, sudden stop and right-hand cornering sections (65.4%, 71.5% and 72.5%, respectively; p=0.001) CONCLUSIONS: Although we found no differences in chest compression quality parameters between the stationary and driving states, the variability in the chest compression depth increased in the driving state. When comparing CPR quality parameters according to driving patterns, we noted a shallower compression depth, increased variability and decreased correct hand position rate in the speed bump, sudden stop and right-hand cornering sections. The clinical significance of these changes in CPR quality during ambulance transport remains to be determined. Future studies on how to reduce changes in the quality of CPR (including research on equipment development) are needed.
Medical subject headings
- Ambulances
- Automobile Driving
- Cardiopulmonary Resuscitation
- Emergency Medical Technicians
- Out-of-Hospital Cardiac Arrest
- Virtual Reality