Comparison of MRI Sequences in Whole-Body PET/MRI for Staging of Patients With High-Risk Prostate Cancer.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 30332285.
- Also identified by DOI 10.2214/AJR.18.20495.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study is to investigate the diagnostic value of various MRI sequences used for whole-body (WB) <sup>18</sup>F-fluorocholine (FCH) PET/MRI staging of patients with high-risk prostate cancer (PCa). This analysis is based on data from a prospective study that included 58 patients with untreated high-risk PCa who underwent integrated WB FCH PET/MRI (n = 10) or FCH PET/CT and WB MRI (n = 48). Metastatic sites were recorded. The standard of reference was histopathologic findings or clinical and imaging follow-up, or both. For each MRI sequence (Dixon T1-weighted, turbo inversion recovery magnitude, WB DWI, and gadolinium-enhanced T1-weighted volumetric interpolated breath-hold examination [VIBE]), acquisition time was recorded, and conspicuity of metastatic lesions was qualitatively assessed by two radiologists using a 4-point ordinal scale (0-3). Total WB acquisition times were 1 minute 25 seconds for Dixon T1-weighted, 15 minutes 7 seconds for turbo inversion recovery magnitude, 16 minutes 33 seconds for WB DWI, and 1 minute 28 seconds for gadolinium-enhanced T1-weighted VIBE. The lesion detection rates were 88.3% (68/77) for Dixon T1-weighted, 94.8% (73/77) for turbo inversion recovery magnitude, 95.2% (40/42) for WB DWI, and 97.4% (75/77) for gadolinium-enhanced T1-weighted VIBE sequences. Moderate or high conspicuity scores were assigned to 62.3% (48/77) of lesions for Dixon T1-weighted, 88.3% (68/77) of lesions for turbo inversion recovery magnitude, 90.5% (38/42) of lesions for WB DWI, and 92.2% (71/77) of lesions for gadolinium-enhanced T1-weighted VIBE sequences. Conspicuity of metastases on gadolinium-enhanced T1-weighted VIBE and WB DWI sequences was higher than that on Dixon T1-weighted sequences (p < 0.0001 and p = 0.0011, respectively). Metastases from prostate cancer are best detected at DWI or gadolinium-enhanced T1-weighted VIBE sequences. The most time-efficient sequence with the highest lesion detection rate and conspicuity is gadolinium-enhanced T1-weighted VIBE.
Medical subject headings
- Magnetic Resonance Imaging
- Multimodal Imaging
- Positron-Emission Tomography
- Prostatic Neoplasms
- Whole Body Imaging