Closed loop bioreactor system for the ex vivo expansion of human T cells.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 30497956.
- Also identified by DOI 10.1016/j.jcyt.2018.10.009 and PMC identifier 6333522.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Translation of therapeutic cell therapies to clinical-scale products is critical to realizing widespread success. Currently, however, there are limited tools that are accessible at the research level and readily scalable to clinical-scale needs. We herein developed and assessed a closed loop bioreactor system in which (i) a highly gas-permeable silicone material was used to fabricate cell culture bags and (ii) dynamic flow was introduced to allow for dissociation of activated T-cell aggregates. Using this system, we find superior T-cell proliferation compared with conventional bag materials and flasks, especially at later time points. Furthermore, intermittent dynamic flow could easily break apart T-cell clusters. Our novel closed loop bioreactor system is amenable to enhanced T-cell proliferation and has broader implications for being easily scaled for use in larger need settings.
Medical subject headings
- Batch Cell Culture Techniques
- Bioreactors
- Cell Proliferation
- T-Lymphocytes