Motor endplate-expressing cartilage-muscle implants for reconstruction of a denervated hemilarynx.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 30548608.
- Also identified by DOI 10.1002/lary.27575 and PMC identifier 8171591.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Tissue engineering of the larynx requires a complex, multiple tissue layer design. Additionally, spontaneous reinnervation of the larynx after recurrent laryngeal nerve (RLN) injury is often disorganized, resulting in subpar function. This study investigates use of tissue-engineered cartilage and motor endplate-expressing (MEE) tissue-engineered skeletal muscle implants for laryngeal reconstruction and the promotion of organized reinnervation after RLN injury. F344 rat primary muscle progenitor cells (MPCs) were isolated. Three-dimensional muscle constructs were created by encapsulating MPCs in type I oligomeric collagen under passive tension. Constructs were then cultured in differentiation medium (MPC control constructs) or induced to form motor endplates (MEE constructs) with neurotrophic agents. Three-dimensional cartilage constructs were created with adipose stem cells differentiated in chondrocyte medium. The muscle and cartilage constructs were implanted into surgically created myochondral defects in the F344 rat larynx with injured or intact (control) RLN. At 1-, 3-, and 6-month timepoints, videolaryngoscopy, electromyography (EMG), histology, and immunohistochemistry were used to assess outcomes. At all timepoints, cartilage-muscle implants were well integrated into host tissue. Functionally, there was increased vocal fold adduction and EMG activity in nerve-injured rats treated with the MEE constructs when compared to those treated with the MPC control constructs. Motor endplate-expressing constructs had increased myofiber cross-sectional area compared to MPC control constructs. Although our laboratory previously demonstrated that muscle and cartilage constructs could be used separately for hemilaryngeal reconstruction, this study suggests combining them with the modification of MEEs rather than MPCs, resulting in improved muscle recovery after recurrent laryngeal nerve injury. NA Laryngoscope, 129:1293-1300, 2019.
Medical subject headings
- Cartilage
- Laryngoplasty
- Motor Endplate
- Muscle, Skeletal
- Nerve Regeneration
- Recurrent Laryngeal Nerve Injuries
- Tissue Engineering