Symmetry Matching of the Medial Acetabular Surface-A Quantitative Analysis in View of Patient-Specific Implants.

Osterhoff, Georg; Petersik, Andreas; Sprengel, Kai; Pape, Hans-Christoph · J Orthop Trauma · 2019

cross_sectional · Level IV

Where this comes from

Abstract

To quantify intrapelvic surface symmetry in reference to a preshaped suprapectineal acetabular implant. In this cross-sectional study, an anatomically preshaped acetabular fracture implant was fitted on 3D surface models of 516 pelvises from a preexisting bone database using a software tool for automated implant fitting (SOMA, Stryker Orthopaedic Modeling and Analytics) of a CAD model of the implant. The distances between bone and the reference implant were measured at 2310 reference points for each hemipelvis. The average distance between the left hemipelvis and the plate was 1.98 mm (median, 10% percentile: 1.45, 90% percentile: 2.78) and 2.0 mm (median, 10% percentile: 1.45, 90% percentile: 2.92) between the right hemipelvis and the plate. There was no significant difference between the 2 hemipelvises (median absolute pairwise delta: 0.25 mm; 10% percentile: 0.04, 90% percentile: 0.82; Wilcoxon, P = 0.064). With regard to the periacetabular surface of the inner pelvis, the pelvis can be considered sufficiently symmetric for using the mirrored contralateral hemipelvis as a template for patient-specific implants in acetabular fracture fixation.

Medical subject headings

Anatomy