Outcomes of Surgical Treatment of Periprosthetic Acetabular Fractures.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 30688860.
- Also identified by DOI 10.1097/BOT.0000000000001400.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Periprosthetic acetabular fractures sustained following acute trauma after total hip arthroplasty are rare and historically have poor outcomes. This article reviews 5 cases and the treatment algorithm used by a single orthopaedic surgeon specializing in acetabular fracture care with a co-surgeon specializing in arthroplasty. Team-based surgical management with arthroplasty- and fracture-trained surgeon(s) is paramount for optimal outcome. The following approach resulted in satisfactory outcomes without need for revision implants. In fracture patterns with columnar involvement, the columns were restored with plates and screws. In fracture patterns with wall involvement, the acetabular component functioned as a template for wall reconstruction with use of a buttress plate. The acetabular component was revised when deemed loose during stress of the component through the surgical approach used for fracture fixation.
Medical subject headings
- Acetabulum
- Arthroplasty, Replacement, Hip
- Fracture Fixation, Internal
- Fractures, Bone
- Periprosthetic Fractures
Anatomy
- hip
- pelvis