Assessing the level of radiation experienced by anesthesiologists during transfemoral Transcatheter Aortic Valve Implantation and protection by a lead cap.
Level IV
Where this comes from
- Record sourced from PubMed, PMID 30699164.
- Also identified by DOI 10.1371/journal.pone.0210872 and PMC identifier 6353158.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Transfemoral Transcatheter Aortic Valve Implantation (TAVI) has become a standard therapy for patients with aortic valve stenosis. Fluoroscopic imaging is essential for TAVI with the anesthesiologist's workplace close to patient's head side. While the use of lead-caps has been shown to be useful for interventional cardiologists, data are lacking for anesthesiologists. A protective cap with a 0.35 lead-equivalent was worn on 15 working days by one anesthesiologist. Six detectors (three outside, three inside) were analyzed to determine the reduction of radiation. Literature search was conducted between April and October 2018. In the observational period, 32 TAVI procedures were conducted. A maximum radiation dose of 0.55 mSv was detected by the dosimeters at the outside of the cap. The dosimeters inside the cap, in contrast, displayed a constant radiation dose of 0.08 mSv. The anesthesiologist's head is exposed to significant radiation during TAVI and it can be protected by wearing a lead-cap.
Medical subject headings
- Anesthesiologists
- Fluoroscopy
- Occupational Exposure
- Radiation Exposure
- Radiation Protection
- Transcatheter Aortic Valve Replacement