Surgical Repair of Aortic Rupture Caused by Retained Neurointerventional Guidewire.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 30703367.
- Also identified by DOI 10.1016/j.athoracsur.2018.12.047.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Retention of guidewire during a neurointervention procedure is extremely rare and potentially lethal. We report a successful operation on an aortic rupture caused by a retained guidewire from a neurointervention procedure 2 years ago. During the operation, we took out the guidewire from both the aortic arch and femoral artery. Postoperative treatment was uneventful. At the 10-month follow-up, the patient remained asymptomatic and computed tomography showed no abnormality.