A new approach to measure the resistance of fabric to liquid and viral penetration.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 30735524.
- Also identified by DOI 10.1371/journal.pone.0211827 and PMC identifier 6368298.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Protective clothing manufacturers routinely test their products for resistance to liquid and viral penetration. Several of the test methods specified by the American Society for Testing and Materials (ASTM) and the International Organization for Standardization (ISO) for penetration testing produce binary results (i.e. pass or fail), deliver imprecise pressure regulation, and do not record the location at which penetration events occur. Instead, our approach measures a continuous variable (time of penetration) during a slow and continuous increase of hydrostatic pressure and retains the location of penetration events. Using a fluorescent dye to enhance visual detection, we evaluate temporal and spatial patterns of penetration events. We then compare the time of liquid penetration with the time of penetration of two bacteriophages (Phi-X174 and MS2). For the fabric tested, the mean viral penetration occurred 0.29 minutes earlier than liquid penetration when solved by logistic regression. The breakthrough time of MS2 was not different from the Phi-X174 bacteriophage. The time of liquid penetration was a latent indicator of the time of viral penetration.
Medical subject headings
- Bacteriophage phi X 174
- Levivirus
- Materials Testing
- Protective Clothing
- Textiles