Sublaminar banding as an adjunct to pedicle screw-rod constructs: a review and technical note on novel hybrid constructs in spinal deformity surgery.
review · Level V
Where this comes from
- Record sourced from PubMed, PMID 30835710.
- Also identified by DOI 10.3171/2018.11.SPINE181154.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Sublaminar implants that encircle cortical bone are well-established adjuncts to pedicle screw-rod constructs in pediatric deformity surgery. Sublaminar bands (SLBs) in particular carry the advantage of relatively greater bone contact surface area as compared to wires and pullout loads that are independent of bone mineral density, in contrast to pedicle screws. Whereas the relevant technical considerations have been reported for pediatric deformity correction, an understanding of the relative procedural specifics of these techniques is missing for adult spinal deformity (ASD), despite several case series that have used distinct posterior tethering techniques for proximal junctional kyphosis prevention. In this paper, the authors summarize the relevant literature and describe a novel technique wherein bilateral tensioned SLBs are introduced at the nonfused proximal junctional level of long-segment ASD constructs.