Frozen-Section Checklist Implementation Improves Quality and Patient Safety.
Where this comes from
- Record sourced from PubMed, PMID 30892600.
- Also identified by DOI 10.1093/ajcp/aqz009.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
An intraoperative consultation (IOC) checklist was developed and implemented aimed at standardizing slide labeling and monitoring metrics central to quality and safety in surgical pathology. Data were collected for all IOC cases over a 9-month period. Slide labeling defect rates and IOC turnaround time (TAT) were recorded and compared for the pre- and postimplementation periods. In total, 839 IOC cases were analyzed. Preintervention slide labeling showed that 85% of cases contained at least one defect (n = 565). Postintervention data revealed that 27% of cases contained at least one defect (n = 274). The improvement was statistically significant (P < .001). Mean TAT was 21.6 minutes preintervention vs 23.2 minutes postintervention, and the change was insignificant (P = .071). The implementation of a standardized IOC reduced slide labeling error. This improvement did not affect mean TAT and may have the increased quality of IOC TAT data reporting. Other metrics affecting patient safety and quality were monitored and standardized.
Medical subject headings
- Checklist
- Frozen Sections
- Patient Safety