Radiographic Calibration With a Prosthetic Femoral Head Allows Accurate Preoperative Templating for Total Hip Arthroplasty.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 30913298.
- Also identified by DOI 10.3928/01477447-20190321-06.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Templating for total hip arthroplasty requires proper radiographic calibration. One option for radiograph calibration is using a cobalt-chrome femoral head ball. The authors reviewed radiographs and clinical data for patients undergoing primary total hip arthroplasty. Radiographs were calibrated using a 28-mm cobalt-chrome femoral head ball. Agreements between templated and actual implant size were calculated. The templated acetabulum matched within one size of the actual acetabulum in 76.7% to 80.0% of cases. The templated femur matched within one size of the actual femur in 83.3% to 93.3% of cases. This technique is an attractive option when a standardized calibration marker is unavailable. [Orthopedics. 2019; 42(3):e346-e349.].