A biomechanical comparison of two arthroscopic suture techniques in biceps tenodesis: whip-stitch vs. simple suture techniques.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 30948215.
- Also identified by DOI 10.1016/j.jse.2019.01.004.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this study was to compare the biomechanical performance of whip-stitch (WS) and simple suture techniques (SST) of the long head of the biceps tendon in suprapectoral intraosseous tenodesis with interference screw fixation. A total of 10 paired cadavers (61.1 ± 4.6 years) were randomized to receive WS or SST biceps tenodesis beginning at the musculotendinous junction. Both groups implemented a No. 2 FiberLoop wire and underwent suprapectoral fixation with a polyetheretherketone interference screw at the bicipital grove. A Materials Testing System performed cyclic testing (500 cycles), followed by load to failure at 1 mm/s. Load, displacement, and time were recorded during cyclic and failure testing. A 2-tailed Student's t-test and χ<sup>2</sup> analysis were performed for failure load and mode of failure, respectively. Two SST specimens and 1 WS specimen failed during cyclic loading via tendon rupture at the screw-tendon interface. There was no significant statistical difference in the cyclic displacement after 500 cycles between the WS (12.9 mm ± 4.4 mm) and SST groups (14.0 mm ± 3.8 mm, P = .2); cyclic strain, defined as the peak displacement at the 500th cycle divided by the initial gauge length, between the WS (0.4 ± 0.2) and SST groups (0.7 ± 0.7, P = .3); maximal load (162.7 N ± 56.8 N vs. 153.1 N ± 39.3 N, respectively, P = .6); and stiffness (50.5 N/mm ± 17.7 N/mm vs. 43.3 N/mm ± 10.9 N/mm, respectively, P = .3). All specimens ruptured at the screw-tendon interface. The WS technique can provide equivalent biomechanical performance to the SST in suprapectoral intraosseous biceps tenodesis with interference screw fixation.
Medical subject headings
- Arthroscopy
- Elbow Joint
- Plastic Surgery Procedures
- Suture Techniques
- Tendon Injuries
- Tendons
- Tenodesis
Anatomy
- elbow