Comparative performance evaluation of four commercial multiplex real-time PCR assays for the detection of the diarrhoea-causing protozoa Cryptosporidium hominis/parvum, Giardia duodenalis and Entamoeba histolytica.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 30958837.
- Also identified by DOI 10.1371/journal.pone.0215068 and PMC identifier 6453453.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Multiplex molecular panels are relentlessly replacing conventional methods for the detection of enteric pathogens from stool samples in clinical and research laboratories. Here we evaluated four commercial multiplex real-time PCR assays for the detection of Cryptosporidium hominis/parvum, Giardia duodenalis and Entamoeba histolytica. The diagnostic performance of the Gastroenteritis/Parasite Panel I (Diagenode), the RIDAGENE Parasitic Stool Panel (R-Biopharm), the Allplex Gastrointestinal Parasite Panel 4 (Seegene) and the FTD Stool Parasites (Fast Track) real-time PCR methods was assessed against a reference panel of 126 well-characterized DNA samples including Cryptosporidium hominis (n = 29), Cryptosporidium parvum (n = 3), Giardia duodenalis (n = 47), Entamoeba histolytica (n = 3), other parasite species (n = 20), and apparently healthy subjects (n = 24). Obtained diagnostic sensitivities ranged from 53-88% for Cryptosporidium hominis/parvum, and from 68-100% for G. duodenalis. The R-Biopharm method achieved the best performance for the detection of Cryptosporidium hominis/parvum both in terms of diagnostic sensitivity (87.5%) and detection limit (a 100-fold increase compared to other tests). The Fast Track method was particularly suited for the detection of G. duodenalis, achieving a 100% sensitivity and a detection limit at least 10-fold superior. Detection of E. histolytica was similarly achieved by all compared methods except Diagenode. Diagnostic performance varied largely depending on the method used and the targeted pathogen species. Factors including test sensitivity/specificity, cost, patient population surveyed, laboratory workflow, and diagnostic algorithm should be carefully considered when choosing the most appropriate multiplex PCR platform.
Medical subject headings
- Cryptosporidiosis
- Diagnostic Tests, Routine
- Diarrhea
- Entamoebiasis
- Feces
- Giardiasis
- Multiplex Polymerase Chain Reaction