Improving <sup>68</sup>Ga-PSMA PET/MRI of the Prostate with Unrenormalized Absolute Scatter Correction.
Where this comes from
- Record sourced from PubMed, PMID 30979819.
- Also identified by DOI 10.2967/jnumed.118.224139.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A limitation of using <sup>68</sup>Ga-labeled prostate-specific membrane antigen (<sup>68</sup>Ga-PSMA) for detection and staging of prostate cancer is a frequently observed halo artifact around the urinary bladder caused by inaccurate scatter correction (SC) of PET data. The aim of this study was to investigate the impact of unrenormalized absolute SC on <sup>68</sup>Ga-PSMA PET quantification in PET/MRI of the prostate in 100 patients. <b>Methods:</b> The PET data of 100 patients were reconstructed twice using standard SC and improved unrenormalized SC. The visual presence of the halo artifact was rated in each PET data reconstruction using 5 grades (0, no halo artifact; 4, severe halo artifact). The number of visible lesions in the pelvis was recorded. SUV<sub>mean</sub> and SUV<sub>max</sub> were measured in the lesions, in the bladder, in the gluteus maximus, and within the halo margin. Furthermore, the signal-to-noise-ratio and image noise were measured in all PET data. Relative differences between standard and unrenormalized SC were calculated. <b>Results:</b> With standard SC, the average grade in the presence of the halo artifact was 2 (moderate halo artifact), whereas for unrenormalized SC, the average grade was 0.9 (slight halo artifact). The same number of congruent lesions (<i>n</i> = 74) was detected for both PET data reconstructions. Relative changes in PET signal-to-noise-ratio and image noise were not statistically significant (<i>P</i> > 0.05). The mean (±SD) increase in SUV<sub>mean</sub> using unrenormalized SC was 23.0% ± 9.2% in the gluteus maximus, 7.1% ± 4.5% in the bladder, 325.4% ± 748.5% in the halo margin, and 12.4% ± 16.8% in all 74 detected lesions. The mean increase using unrenormalized SC in SUV<sub>mean</sub> was 17.5% for lesions inside the halo margin (38 lesions) and 6.9% for lesions outside the halo margin (36 lesions). <b>Conclusion:</b> For PET/MRI of prostate cancer using <sup>68</sup>Ga-PSMA, a proper SC is important to ensure the best possible diagnostic quality and PET quantification. Unrenormalized absolute SC significantly reduces the halo artifact around the bladder and improves PET/MRI of the prostate.
Medical subject headings
- Image Enhancement
- Magnetic Resonance Imaging
- Membrane Glycoproteins
- Multimodal Imaging
- Organometallic Compounds
- Positron-Emission Tomography
- Prostate