To compare functional outcomes and magnetic resonance image (MRI) tendon integrity following either the suture bridge or the knotless cinch-bridge technique used for arthroscopic double-layer rotator cuff repair. 37 prospectively enrolled patients (46-76 years), who were treated with arthroscopic double-layer rotator cuff repair (group 1: suture bridge n = 20, group 2: cinch bridge n = 17) were clinically and radiographically assessed before and at an average of 24.0 ± 4.7 months after the procedure. Shoulder function was evaluated by the constant score (CS), range of motion, and various patient-related scores. Repaired tendon integrity was evaluated by MRI. Peri- and postoperative complications were recorded. All functional and patient-related scores significantly improved from pre- to postoperative. Significantly better postoperative CS (P = 0.037), flexion (P < 0.001), and abduction (P = 0.009) were detected after arthroscopic cinch compared to suture-bridge repair. The mean CS improvements from baseline to follow-up were not significantly different between the groups (n.s.). Patient-related scores did not show any statistical significant differences. The MRI healing rate following arthroscopic double-layer repair with the suture- and cinch-bridge technique was 95% and 94%, respectively. Fatty infiltration regarding the supraspinatus and infraspinatus increased in 55% and 35% (group 1) and in 53% and 48% (group 2), respectively. Muscle hypotrophy remained stable in all patients. Overall, 92% of the patients were very satisfied or satisfied with the procedure. No complications were detected. Arthroscopic knotless double-layer rotator cuff repair with the cinch-bridge technique showed higher CS, forward flexion, and abduction values, as well as similar patient-related short-term outcome and MRI integrity compared to the suture-bridge technique. These results highlight the potential importance of less tendon strangulation for better clinical short-term outcome. Level II, prospective comparative study.
Medical subject headings
- Arthroscopy
- Rotator Cuff Injuries
- Suture Techniques
Anatomy
- shoulder