Reliability and concurrent validity of a mobile application to measure thoracolumbar range of motion in low back pain patients.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 31127756.
- Also identified by DOI 10.3233/BMR-181396.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Smartphone devices have been used to measure range of motion (ROM) in different joints. To verify the concurrent validity of thoracolumbar ROM using a mobile application and a digital inclinometer, as well as the intrarater reliability of individuals with and without back pain. One investigator was responsible for measuring the ROM during the evaluations performed on 20 asymptomatic subjects and 20 symptomatic subjects in two consecutive days. Regarding to the concurrent validity, the Intraclass Correlation Coefficients (ICC) were classified as very good for all analyzed movements. For intrarater reliability, the mobile application had ICC varying between good and very good for the symptomatic subjects and very good for asymptomatic subjects. The mobile application may be considered a valid and reliable tool to assess thoracolumbar ROM for both asymptomatic and chronic low back pain subjects.
Medical subject headings
- Low Back Pain
- Lumbar Vertebrae
- Mobile Applications
- Range of Motion, Articular
- Thoracic Vertebrae
Anatomy
- lumbar spine
- thoracic spine