Fully closed-loop insulin delivery improves glucose control of inpatients with type 2 diabetes receiving hemodialysis.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 31133457.
- Also identified by DOI 10.1016/j.kint.2019.03.006.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Inpatient diabetes management of those on hemodialysis poses a major challenge. In a post hoc analysis of a randomized controlled clinical trial, we compared the efficacy of fully automated closed-loop insulin delivery vs. usual care in patients undergoing hemodialysis while in hospital. Compared to control patients receiving conventional subcutaneous insulin therapy, those patients receiving closed-loop insulin delivery significantly increased the proportion of time when a continuous glucose monitor was in the target range of 5.6-10.0 mmol/l by 37.6 percent without increasing the risk of hypoglycemia. Thus, closed-loop insulin delivery offers a novel way to achieve effective and safe glucose control in this vulnerable patient population.
Medical subject headings
- Diabetes Mellitus, Type 2
- Hypoglycemic Agents
- Insulin Infusion Systems
- Kidney Failure, Chronic
- Renal Dialysis