Percutaneous Aortic Valve Closure in Patient With Left Ventricular Assist Device and Dilated Aortic Annulus.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 31207247.
- Also identified by DOI 10.1016/j.athoracsur.2019.04.081.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Percutaneous transcatheter intervention for aortic regurgitation secondary to implantation of a continuous-flow left ventricular assist device remains challenging, because of the minimal global experience with these procedures. Two treatment options are available: transcatheter aortic valve replacement, which is not always feasible when a dilated aortic annulus is present, and percutaneous aortic valve occlusion. We report a successful percutaneous closure of the aortic valve using an oversized Amplatzer patent foramen ovale multifenestrated device (St Jude Medical, Saint Paul, MN) to treat aortic regurgitation associated with dilated aortic annulus in a patient with a continuous-flow left ventricular assist device.
Medical subject headings
- Aortic Valve
- Aortic Valve Insufficiency
- Heart-Assist Devices