Adaptive Pulse Wave Imaging: Automated Spatial Vessel Wall Inhomogeneity Detection in Phantoms and in-Vivo.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 31265387.
- Also identified by DOI 10.1109/TMI.2019.2926141 and PMC identifier 6938555.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Imaging arterial mechanical properties may improve vascular disease diagnosis. Pulse wave velocity (PWV) is a marker of arterial stiffness linked to cardio-vascular mortality. Pulse wave imaging (PWI) is a technique for imaging the pulse wave propagation at high spatial and temporal resolution. In this paper, we introduce adaptive PWI, a technique for the automated partition of heterogeneous arteries into individual segments characterized by most homogeneous pulse wave propagation, allowing for more robust PWV estimation. This technique was validated in a silicone phantom with a soft-stiff interface. The mean detection error of the interface was 4.67 ± 0.73 mm and 3.64 ± 0.14 mm in the stiff-to-soft and soft-to-stiff pulse wave transmission direction, respectively. This technique was tested in monitoring the progression of atherosclerosis in mouse aortas in vivo ( n = 11 ). The PWV was found to already increase at the early stage of 10 weeks of high-fat diet (3.17 ± 0.67 m/sec compared to baseline 2.55 ± 0.47 m/sec, ) and further increase after 20 weeks of high-fat diet (3.76±1.20 m/sec). The number of detected segments of the imaged aortas monotonically increased with the duration of high-fat diet indicating an increase in arterial wall property inhomogeneity. The performance of adaptive PWI was also tested in aneurysmal mouse aortas in vivo. Aneurysmal boundaries were detected with a mean error of 0.68±0.44 mm. Finally, initial feasibility was shown in the carotid arteries of healthy and atherosclerotic human subjects in vivo ( n = 3 each). Consequently, adaptive PWI was successful in detecting stiffness inhomogeneity at its early onset and monitoring atherosclerosis progression in vivo.
Medical subject headings
- Image Interpretation, Computer-Assisted
- Ultrasonography