Comparison of Two Commercial Matrix-Assisted Laser Desorption/Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS) Systems for Identification of Nontuberculous Mycobacteria.
Where this comes from
- Record sourced from PubMed, PMID 31314059.
- Also identified by DOI 10.1093/ajcp/aqz073 and PMC identifier 6733354.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This multicenter study's aim was to assess the performance of two commercially available matrix-assisted laser desorption/ionization time of flight mass spectrometry systems in identifying a challenge collection of clinically relevant nontuberculous mycobacteria (NTM). NTM clinical isolates (n = 244) belonging to 23 species/subspecies were identified by gene sequencing and analyzed using Bruker Biotyper with Mycobacterial Library v5.0.0 and bioMérieux VITEK MS with v3.0 database. Using the Bruker or bioMérieux systems, 92% and 95% of NTM strains, respectively, were identified at least to the complex/group level; 62% and 57%, respectively, were identified to the highest taxonomic level. Differentiation between members of Mycobacterium abscessus, M fortuitum, M mucogenicum, M avium, and M terrae complexes/groups was problematic for both systems, as was identification of M chelonae for the Bruker system. Both systems identified most NTM isolates to the group/complex level, and many to the highest taxonomic level. Performance was comparable.
Medical subject headings
- Nontuberculous Mycobacteria
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization